Temperature  Sensor / Humidity Sensor 

                              Barometric Pressure Sensor / Solar Radiation Sensor

 

  ±â »ó                                                  Wind Speed Sensor

 

Ranges

Starting speed

Accuracy

Temp/Ranges

 Met One 010C

0-125 mph or

0-60meters/second

0.5 mph or .22 meters/second

±1% or 0.15 mph

-50°c to +65¡É

 Met One 013

0-150 mph

1.0 mph

±0.25 mph or 2%

-50¡É to +70¡É

 Met One 014A

0-100 mph

1 mph

±0.25 mph or 1.5%FS

-50¡É to +70¡É

 Met One 591

0-100 mph

1.0 mph

±0.25 mph or 1.5%

-50¡É to +70¡Éx

 Wind Direction Sensor

 

Ranges

Starting speed

Accuracy

Temp/Ranges

 Met One 020C

0-360°

0.5 mph

±3°

-50¡É to +65¡É

 Met One 021C

0-360°

0.5 mph

±2°

-50¡É to +65¡É

 Met One 024A

0-360°

1 mph

±5°

-50¡É to +70¡É

 Met One 023

0-360°

1.5 mph

±10°

-50¡É to +70¡É

 Met One 590

0-360°

(0-540° when used with 540°Translator Module)

1 mph

±5° Standard

-50¡É to +70¡É

 Temperature  Sensor

 

Ranges

Linearity

Accuracy

Time Constant

Met One 063-1

-50¡É to + 50¡É

±0.15¡É

±0.1¡É

60 Seconds

Met One 063-2

0¡É to + 100¡É

±0.21¡É

±0.15¡É

60 Seconds

Met One 592-1

-30¡É to + 50¡É

±0.15¡É

±0.15¡É

10 Seconds in still air

Met One 592-2

-50¡É to + 50¡É

±0.15¡É

±0.1¡É

10 Seconds in still air

 Humidity Sensor 

 

Ranges

Accuracy

Temperature

Coefficient

Temp/Ranges

 Met One 593

0-100% Relative

Humidity

10-90% ±3%

0.07% per 1¡É

0-40¢µ to 175¢µ

 Met One  083D

0-100% Relative

Humidity

10-90% ±2%

0.04% RH/¡É

-20¡É to +60¡É

Barometric Pressure Sensor

 

Ranges

Resolution

Accuracy

Cable

 Met One 090D

26-32" Hg

Infinite

±0.04 in Hg(±1.35mbar)

or ±0.125% FS

#1168-xx

(xx=length in feet)

 Met One 594

26-32 inches Hg

Others available

Infinite

±0.125%FS

3-wire shilded

control cable

Solar Radiation Sensor

 

Temp/Dependence

Sensitivity

Response time

 

 Met One 095

±1.5% Constancy

from -20 to +40¡É

11 mV/kwatt meter-2 ,approx

5 second

(1/e signal)

 

 Met One 096

±0.15%/degree C,

maximum

8.0 mV/kwatt meter-2with 100 Ohm lor approx

10 microseconds

(10% to 90%)

 

 Met One 097

N/A

75 mV/kwatt  meter-2,approx

10.5 seconds

 

 Met One 394

±1% Constancy

from -20 to +40¡É

9 mV/kwatt meter-2, approx.

1 second

(1/e signal)