Harim Engineering, Inc.

 

  

      Home / About Harim / Product / User List / Site Link

Korean Home

 

 

 

 

 

TE-6070-BL High Volume PM-10 MFC Monitor in Ambient Air

     TE-6070-BL                         PM-10 Brushless High Volume Air Sampling System includes;
                                                       Size selective inlet,(<10 Micron cut Size), Anodized Aluminum
                                                       Shelter, 8" * 10" Stainless Steel filter Holder, with Probe Hole,
                                                       Brushless Blower Motor,    Continuous Flow/Pressure Recorder,
                                                       Elapsed Time Indicator, Brushless Mass Flow Controller w/20-60
                                                       SCFM Air Flow Probe,Filter  Media Holder, and 7-Day
                                                       Mechanical Timer (110v/60hz or 220v/50hz)
   

SPECIFICATIONS

  Inlet collection efficiency

  Meet EPA'S PM-10 Code of Federal Regulations

  Appendix J to part 50

  Flow rate

  40 cfm (adjustable) (1.02 to 1.24§©)

  Filter media

  Micro-Quartz filter media 8" * 10" for PM10 (TE-QMA)

  Flow control

  MFC(TE-300-310)

  Motor blower

  Brushless 3 stage motor (TE-117415)

  Flow Indicator

  Flow/pressure recorder (TE-5009) with TE-106 Charts

  Mechanical programmable timer

  7-day mechanical timer (TE-5007)

  Elapsed time indicator device

  Elapsed time indicator (TE-5012)

  Shipping Information

 

  Size

  22.5" * 20"* 45.5" sampler carton

  32"* 32" * 25.5" inlet carton

  Weight

  65 lbs-sampler carton, 60 lbs-inlet carton

  Assembled Space Requirement

  30" round * 64" high

  Power Requirement

  Single phase with earth ground

  110v/60hz or 220v/50hz

  Motor Specifications

  110v/60hz or 220v/50hz - Part #TE117415,

  Ball bearing, tangential discharge

  Altitude Application

  to 10,000 feet above sea level

  Ambient Temperature Application

  -30 to +50¡É

  Relative Humidity Application

  0-100%

  Sample Delay Start Range

  0-7 days

  Running amps

  11 amps