Harim Engineering, Inc.

 

  

      Home / About Harim / Product / User List / Site Link

Korean Home

 

 

 

 

TE-5170 High Volume TSP MFC Monitor in Ambient Air

            TE-5170                           TSP MFC (Mass Flow Controlled) High Volume Air Sampler:
                                                          Complete with outdoor anodized aluminum shelter, aluminum
                                                          blower motor assembly, 8" * 10" stainless steel filter holder,
                                                          mess flow controller with 20-60 scfm air flow probe, 7- day
                                                          mechanical timer, elapsed time indicator and continuous
                                                          flow/pressure record (110v/60hz or 220v/50hz)

SPECIFICATIONS

  Inlet collection efficiency

  Meet EPA'S Code of Federal Regulations

  Appendix B to part 50

  Flow rate

  39 cfm - 60 cfm (1.1 to 1.7§©)

  Filter media

  Glass Fiber Filter 8" * 10" (TE-G653)

  Flow control

  Mass Flow Controlled with 20 to 60 scfm Air Flow   Probe

  (TE-300-310)

  Motor blower

  2-stage vacuum 0.6 HP 110v/60hz(TE-116311)

                                       220v/50hz(TE-116312)

  Flow Indicator

  Flow/pressure recorder (TE-5009)

  Mechanical programmable timer

  7-day mechanical timer (TE-5007)

  Elapsed time indicator device

  Elapsed time indicator (TE-5012)

  Shipping Information

 

  Size

  22.5" * 20"* 45.5" sampler carton

  14" * 14"* 19" lid/filter holder carton

  Weight

  75 lbs-sampler carton, 8 lid/filter carton

  Assembled Space Requirement

  24" square * 64" high

  Power Requirement

  Single phase with earth ground

  110v/60hz or 220v/50hz

  Motor Specifications

  110v/60hz-part #TE-116311, 2-stage vacuum 0.6HP,

  double ball bearing thru-flow discharge

  220v/50hz-part #TE-116312, 2-stage vacuum 0.6 HP,

  ball/sleeve bearing thru-flow discharge

  Altitude Application

  to 10,000 feet above sea level

  Ambient Temperature Application

  -30 to +50¡É

  Relative Humidity Application

  0-100%

  Sample Delay Start Range

  0-7 days

  Start up amps

  12 amps

  Running amps

  7 amps